​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​This is the most comprehensive and most widely used type of certification that involves:

  • (a) auditing of the factory quality management system for compliance with ISO 9001 requirements, and

  • (b) assessment of the product’s conformance with the standard specification.

The factory must satisfactorily meet both requirements in order to be granted a license to use the DCL Mark on their product.

The audit of the factory quality management system is carried out in accordance with the requirements of ISO 9001 standard for quality management systems. It consists of an initial audit of the factory and its management and followed by regular surveillance audit to ensure continuing compliance with the requirements.

Assessment of the product consist of initial type testing on samples collected during the initial audit of the factory and followed by surveillance testing of the product in the market as well as from factory. In order to be certified, the test results must meet the requirements of the product standard specification.

CERTIFICATION THROUGH FACTORY ASSESSMENT (LICENSING FOR THE USE OF THE DCL MARK)

Under this scheme, a supplier may apply for certification of his product against recognized international, national, or local specifications. DCLD shall carry out initial type testing of the product against the relevant standard specification requirements by selecting random samples and sending them to recognized laboratories for testing. Certification auditors will then carry out assessment of the factory quality management system against the requirements of ISO 9001 standard. When the results of the type testing and factory assessment are satisfactory, the supplier is granted a license to affix the DCL-MARK on their product. The Mark is an indication that the product has been certified as having complied with the relevant standard specifications.

HOW TO AVAIL OF THE CERTIFICATION SERVICE

Applicants for certification through factory assessment may submit their application using form DM-DCLD-F-IC-2001​. The general rules, procedures and requirements for this scheme are given in DM-DCLD-RD-DP21-​2001​(IC). The specific requirements for each particular product are given in the “Specific rules” for that particular product. The currently available certification schemes and their corresponding specific rules can be found through this link:

 

Product Category

Title of Certification Scheme

Remarks/ Application

Specific Rules

Paints, coatings, adhesives, sealants

Low emitting materials (Paints, coatings adhesives sealants) as per Dubai Green Building Regulation and Specifications (GBRS)

Mandatory as per DMCircular (198) 2014

RD-DP2​1​-2180 ​​(IC)

PC Wire Strand

Steel strand, uncoated, seven-wire for pre-stressed concrete as per ASTM A 416

Mandatory requirement under DM Circular No(184)2012-PC Wire Strand-Couplers

RD-DP21-2131 (IC)

High tensile steel wire and strand for pre-stressing of concrete as per BS 5896: 1980

Mandatory requirement under DM Circular No(184)2012-PC Wire Strand-Couplers

RD-DP21-2132 (IC)

​High tensile steel wire and strand for pre-stressing of concrete as per BS 5896: 2012


​Mandatory requirement under DM Circular No(184)2012-PC Wire Strand-Couplers
RD-DP21-2200 (IC)
​Post tension anchorage for pre stressed concrete as per ACI 318 and EAD (European Assessment Document)
​Voluntary
RD-DP21​-2202 (IC)

Cold reduced steel wire for the reinforcement of concrete
(As per BS 4482:1985 Amd No. 1:1997 Amd 2: 2001) Through Factory Assessment

Mandatory requirement under DM Circular No(184)2012-PC Wire Strand-Couplers

RD-DP21-2175 (IC)

Thermal Insulation

Polystyrene thermal insulation (extruded and expanded) as per ASTM C 578 (Mandatory)

Mandatory requirement under B&HD Circular 132-2005

RD-DP21-​2106 (IC)

Polystyrene thermal insulation (Extruded) as per BS EN 13164 (Mandatory)

Mandatory requirement under B&HD Circular 132-2005

RD-DP21-2188 (IC)

Mineral fiber pipe insulation as per ASTM C 547 (Mandatory)

Mandatory requirement under B&HD Circular 132-2005

RD-DP21-​2107 (IC)

Mineral fiber block and board thermal insulation as per ASTM C 612 (Mandatory)

Mandatory requirement under B&HD Circular 132-2005

RD-DP21-2108 (IC)

Mineral fiber blanket thermal insulation as per ASTM C 553 (Mandatory)

Mandatory requirement under B&HD Circular 132-2005

RD-DP21-2109 (IC)

Cellular glass thermal insulation as per BS EN 13167 (Mandatory)

Mandatory requirement under B&HD Circular 132-2005

RD-DP21-2110 (IC)

Factory made mineral wool thermal insulation as per BS EN 13162

Mandatory requirement under B&HD Circular 132-2005

RD-DP​21-2130 (IC)

Spray applied polyurethane thermal insulation as per ASTM C 1029 (Mandatory)

Mandatory requirement under B&HD Circular 132-2005

RD-DP21-2112 (IC)​

Mineral fiber blanket thermal insulation for light frame construction as per ASTM C 665 (Mandatory)

Mandatory requirement under B&HD Circular 132-2005

RD-DP21-2114 (IC)

Polyurethane thermal insulation as per BS EN 13165

Mandatory requirement under B&HD Circular 132-2005

RD-DP21-2124 (IC)

​Rigid Polyisocyanurate Thermal Insulation Board as per ASTM C1289
​Mandatory requirement under B&HD Circular 132-2005
​RD-DP21-2207 (IC)

Phenolic Foam thermal insulation as per BS EN 13166

Mandatory requirement under B&HD Circular 132-2005

RD-DP21-2186 (IC)

In-situ formed sprayed PUR/PIR thermal insulation as per EN 14315-1

Mandatory requirement under B&HD Circular 132-2005

RD-DP21-2187 (IC)

Pipe and Duct Insulation
as per Clause 502.11 of the 2010 Dubai Green Building Regulations and Specifications

Mandatory as per DM Circular (198) 2014

RD-DP​21-2185 (IC)

Reflective insulation as per AS-NZS 4859.1

Mandatory requirement under B&HD Circular 132-2005

RD-DP21-2142 (IC)

Reinforcing Steel Bars

Steel bars for concrete reinforcement AS PER ASTM A 615

Mandatory requirement under DM Circular (159) 2007

RD-DP21-2128 (IC)

Reinforcing steel bars as per BS 4449: 2005

Mandatory requirement under DM Circular (159) 2007

RD-DP21-2129 (IC)

Carbon Steel bars for the reinforcement of concrete as per BS 4449:1997 with Amd 1

Mandatory requirement under DM Circular (159) 2007

RD-DP21-2147 (IC)

Steel Bars for Concrete Reinforcement as per ASTM A 1035

Mandatory

RD-DP21-2168 (IC)

Steel for the Reinforcement of Concrete-Ribbed Bars
(As per ISO 6935-2)

Mandatory

RD-DP21-2181 (IC)

Reinforcement couplers for mechanical splices of bars (as per ISO 15835-1)

Mandatory

RD-DP2​1-2189 (IC)

Precast Concrete Blocks

Precast Concrete Masonry Block as per DMS 1 Part 1

Mandatory requirement under Local Order 44

RD-DP21-2169 (IC)

Precast Concrete Filler Blocks as per DMS 1 Part 2

Mandatory requirement under Local Order 44

RD-DP21-2170 (IC)

Aerated Autoclaved Concrete Masonry Units as per DMS 1 Part 3

Mandatory requirement under Local Order 44

RD-DP21-2173(IC)

Precast Concrete Paving Blocks as per DMS 1 Part 4

Mandatory requirement under Local Order 44

RD-DP21-2172 (IC)

Concrete Polystyrene Sandwich Masonry Blocks as per DMS 1 Part 5

Mandatory requirement under Local Order 44

RD-DP21-2174 (IC)

Ready-Mixed Concrete Plants

Ready-Mixed Concrete Plants in Accordance with Administrative Decision (316) 2012 and DMS 026

Mandatory requirement under Circular (192) 2013

RD-DP21-2​177 (IC)

Solar Collector and

Solar water 

Heating​ System

Solar Collectors as per BS EN 12975-1

Mandatory requirement under Circular (183) 2011

RD-DP21-2178 (IC)

Solar water heating system as per BS EN 12976-1

Mandatory requirement under Circular (183) 2011

RD-DP21-2199 (IC)

Glazed Glass

Glazed glass as per 2010 Dubai Green Building Regulations and Specifications

Mandatory as per DM Circular (198) 2014

RD-DP21-​2192 (IC)

Miscellaneous products under voluntary schemes

Roof, Deck and Balcony Drains as per ASME A112.6.4

Voluntary

RD-DP21-2182 (IC)

Floor and Trench Drains as per ASME A112.6.3

Voluntary

RD-DP21-2183 (IC)

Cleanouts as per ASME A112.36.2

Voluntary

RD-DP21-2190 (IC)

Mortar for masonry – Rendering and plastering mortar as per EN 998-1

Voluntary

RD-DP21-​21​93 (IC)

Steel Fabric for the Reinforcement of Concrete (as per BS 4483)

Voluntary

RD-DP21-2191 (IC)

Polypropylene pipes as per DIN 8078

Voluntary

RD-DP21-2119 (IC)

Manhole Cover as per BS EN 124

Voluntary

RD-DP21-2116 (IC)

Radiation Control Coating as per ASTM C 1483

Voluntary

RD-DP21-2118 (IC)

Pulverized Fuel Ash as per BS 3892

Voluntary

RD-DP21-2121 (IC)

Coal fly ash for use in concrete as per ASTM C 618

Voluntary

RD-DP21-2137 (IC)

Fly ash for concrete as per BS EN 450-1

Voluntary

RD-DP21-2125 (IC)

Plastic pipes for non-pressure underground drainage and sewerage as per EN 13476-2

Voluntary

RD-DP21-2194(IC)

Concrete Admixtures as per BS EN 934-2

Voluntary

RD-DP21-2195 (IC)

​Admixtures to Inhibit Chloride-Induced Corrosion
Reinforcing Steel in Concrete As per ASTM C1582 − 11
​Voluntary
RD-DP21-2201 (IC)

Gypsum Plasterboards as per BS EN 520

Voluntary

RD-DP21-2197 (IC)

Gypsum Boards as per ASTM C1396

Voluntary

RD-DP21-2198 (IC)

​Gypsum blocks as per EN 12859
​Voluntary
RD-DP21-2205 (IC)
​Steel fibres for concrete as per EN 14889-1
​Voluntary
RD-DP21-2203 (IC)
​Mortar for masonry as per EN 998-2
​Voluntary
RD-DP21-2206 (IC)
​​Cement as per ASTM C 150 R1
​Voluntary
RD-DP21-2208 (IC)​​
​Cement as per BS E​N 197-1-2011 R1
​​Voluntary
RD-DP21-2209 (IC)
​​Fire Safety​ Requirements of Thermal Insulation Materials as per the UAE Fire and Life Safety Code of Practice
​Voluntary

RD-DP21-2210 (IC)

                                                        

DOWNLOAD FORMS AND PROCEDURES

Certification Fees varies with different schemes.  Fee structure for specific schemes can be requested through the contact information below.  A formal certification proposal with all details will be sent to applicants.

Link to the List of Certified Products Under Factory Assessment

 

To Apply for the Service please click below:  Request for Factory Assessment Certification


DOWNLOAD QR CODE FOR "LIST OF CERTIFIED PRODUCTS"

For more information, please contact:

Products Conformity Assessment Section
Dubai Central Laboratory Department
Tel + 9714 3027555
Fax + 9714 3351127
e-mail: certification@dm.gov.ae

P.O.Box 67, Dubai, U.A.E.

​ 


​​All the files format PDF/ 2010-2018/ size less than 15 MB
You do not have Acrobat Reader? Click here to download it